<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-30 02-58-52
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 4/5, 33 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
8 kHz 11 kHz 8948 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,2 dBr -1,54 dBr -0,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 2:58, 30.06.2024
RT
"Nazory a argumenty - Novi lidri EU a vyhledy nekterych postso..."
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 11 kHz MIN: 8 kHz % above 77 kHz: 0,0000 Acquired: 2024/06/30 2:58:50 Total samples: 8948 Equivalent time: 0:07:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -0,9 dBr MIN: -2,2 dBr AVE: -1,54 dBr % above 0,2 dBr: 0,0 Last value: -1,0 dBr (2024/06/30 2:58:50) 02:44 02:46 02:48 02:50 02:52 02:54 02:56 02:58 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality